Check Point Reference: | CPAI-2013-3497 |
Date Published: | 4 Nov 2013 |
Severity: | High |
Last Updated: | Monday 07 November, 2016 |
Source: | |
Industry Reference: | CVE-2013-3568 |
Protection Provided by: |
Security Gateway |
Who is Vulnerable? | |
Vulnerability Description | A remote command execution vulnerability has been reported in Belkin Linksys WRT110 firmware. The vulnerability is due to the Web interface's failure to sanitize ping targets as well as a lack of CSRF tokens. A remote attacker could exploit this vulnerability by sending a malicious HTTP request to the victim. Successful exploitation of this vulnerability can result in the execution of arbitrary code in the context of the target user. |
This protection will detect and block attempts to exploit this vulnerability.
In order for the protection to be activated, update your Security Gateway product to the latest IPS update. For information on how to update IPS, go to SBP-2006-05, click on Protection tab and select the version of your choice.
This protection's log will contain the following information:
Attack Name: HTTP Protocol Inspection.
Attack Information: Belkin Linksys WRT110 remote command execution